Welcome to the Wire Quality Gate!
Start
 
What Value Stream is this on?


 
Is this fixture gas or electric?


 
What type of fixture is this?


 
Does the hang straight have a reducer soldered in it?


 
Does the glass pulled match the glass requested on the work order?


 
Did you have to add extra torque when connecting the hook to the down-rod?

     
 
What is the length of the down-rod?

 
Is the length of P-10 stem to the cluster equal to 19.77"?

     
 
Is the length of P-10 stem to the cluster equal to 40.19"?

     
 
Is the length of P-10 stem to the cluster equal to 40.21"?

     
 
Is the length of P-10 stem to the cluster equal to 20.21"?

     
 
Is the length of P-10 stem to the cluster equal to 19.92"?

     
 
What is this fixture's job number? *

Format: XXXXX-XX
 
If multiple quantities on this job number, what number is this of the total listed on work order?

Note: there should a 'x of x' handwritten on the work order.
 
What is this fixture's serial number?

Format: XXXX-XXXX (Note: make sure the location of the sticker matches the FWI)
 
Is there a flag for inspection (red stamp) on the work order?


 
Did you pull the shades for this order?

     
 
Are the swivels oriented according to the print-sets?

     
 
Did you verify the serial tag was placed in the install booklet?

Is the rod flush with the wall mounting bracket?

     
 
Is the dimmer switch locked in place and will not spin?

     
 
Are there any extra line items or notes on the work order that affect the build?

 
Was this fixture wired for standard or international?


 
What type of wire was used?


 
What type of socket was used?

Fill in the blank.
 
What color of wire was used and does it correspond to the finish?


 
Does the wiring protection match the FWI?

(i.e. heat shrink, pipe inserts, grommets, electrical tape, abrasion sleeve)
     
 
Did the fixture pass the Hi-Pot (ground fault) testing? *

Note: do not Hi-Pot LED fixtures without drivers.
     
 
Why did it not pass the Hi-Pot (ground fault)?

 
Did the fixture pass the Hi-Pot (short circuit) testing? *

Note: do not Hi-Pot LED fixtures without drivers.
     
 
Why did it not pass the Hi-Pot (short circuit)?

 
Did the fixture pass the Polarity Continuity testing? *

     
 
Why did it not pass the Polarity Continuity?

 
Did the fixture pass the Ground Continuity testing? *

     
 
Why did it not pass the Grounding Continuity?

 
Did you light bulb test each socket with passing results? *

Note: for multi-socket fixtures, make sure you put a bulb in each socket prior to testing.
     
 
Why did it not pass the light bulb testing?

 
Does the ground screw and grounding wire match the FWI?


 
What rating label was placed on the fixture?

Note: make sure the location of the sticker matches the FWI.

 
Was RTV added to the exit hole?


 
Was the UL label placed on the fixture?

     
 
If applicable, was the Patent Pending sticker placed on the fixture and the box?

     
 
What serial number is on the UL label?

Format: E298xxxxx (enter all digits)
 
What Max Wattage label was placed on the fixture?

Note: make sure the location of the sticker matches the FWI.

 
Are the candle sleeves straight, aligned with the top of the socket, and free of glue residue?

Note: use a retainer clip instead of glue if possible.

 
If ceiling flushmount or wall fixture, have the bent arms that protrude through backplate been trimmed to 1-2 threads above nut?

Note: use a retainer clip instead of glue if possible.

 
Was the mounting plate installed and did it fit correctly?


 
Is the gas burner assembled correctly and secured to the stand-off?

     
 
Is the fixture free of scratches and dents from the assembly process? *

     
 
Do you have all loose parts/hardware required to move to the next step?

(i.e. crossbar, loop/screw collar with reducer, screws, wire nuts, bulbs)
     
 
Did you remember to include the cross-bar?


 
Did this fixture pass this Quality Gate the first time with no rework, touch up, etc.?

     
 
Choose an INT code for primary issue found at this Quality Gate:


 
Choose an INT code for secondary issue found at this Quality Gate:


 
Choose an INT code for tertiary issue found at this Quality Gate:


 
Add any notes or detailed descriptions of the non-conformance(s):